Chapter 6 Configuring Host - Cisco MDS 9216 Configuration Manual

Mds 9000 series san volume controller
Hide thumbs Also See for MDS 9216:
Table of Contents

Advertisement

Isolating Host Traffic
0x6a0009
0x6a000c
Total number of entries = 6
Enter the MDS configuration mode and create a zone called host-finance in VSAN 1.
Step 2
switch# config t
switch(config)# zone name host-finance vsan 1
switch(config-zone)#
Assign members to the host-finance zone.
Step 3
switch(config-zone)# member pwwn 21:00:00:e0:8b:09:e7:04
switch(config-zone)# member pwwn 22:20:00:05:30:00:11:69
switch(config-zone)# member pwwn 21:23:00:05:30:00:11:69
switch(config-zone)# member pwwn 22:23:00:05:30:00:11:69
switch(config-zone)# member pwwn 21:20:00:05:30:00:11:69
Create a zone called host-marketing in VSAN 1.
Step 4
switch(config)# zone name host-marketing vsan 1
switch(config-zone)#
Assign members to the host-marketing zone.
Step 5
switch(config-zone)# member pwwn 21:00:00:e0:8b:09:f0:04 --> Host marketing
switch(config-zone)# member pwwn 22:20:00:05:30:00:11:69
switch(config-zone)# member pwwn 21:23:00:05:30:00:11:69
switch(config-zone)# member pwwn 22:23:00:05:30:00:11:69
switch(config-zone)# member pwwn 21:20:00:05:30:00:11:69
Exit to the MDS configuration mode and create a zone set called main-zset in VSAN 1
Step 6
switch(config-zone)# exit
switch(config)# zoneset name main-zset vsan 1
switch(config-zoneset)#
Assign the host-finance zone and the host-marketing zone as members of the main-zset zone set.
Step 7
switch(config-zoneset)# member host-finance
switch(config-zoneset)# member host-marketing
Exit to the MDS configuration mode.
Step 8
switch(config-zoneset)# exit
switch(config-zone)# exit
switch(config)#
Activate the main-zset zoneset in VSAN 1.
Step 9
switch(config)# zoneset activate name main-zset vsan 1
Zoneset activation initiated. check zone status
Exit to the MDS EXEC mode and verify the active zoneset in VSAN 1.
Step 10
switch(config)# exit
switch# show zoneset active vsan 1
zoneset name main-zset vsan 1
zone name host-finance vsan 1
* fcid 0x6a0200 [pwwn 21:00:00:e0:8b:09:e7:04]
* fcid 0x6a0003 [pwwn 22:20:00:05:30:00:11:69]
* fcid 0x6a0006 [pwwn 21:23:00:05:30:00:11:69]
* fcid 0x6a0009 [pwwn 22:23:00:05:30:00:11:69]
* fcid 0x6a000c [pwwn 21:20:00:05:30:00:11:69]
zone name host-marketing vsan 1
Cisco MDS 9000 Family SAN Volume Controller Configuration Guide
6-2
N
22:23:00:05:30:00:11:69 (Cisco)
N
21:20:00:05:30:00:11:69 (Cisco)
Chapter 6
Configuring Hosts
scsi-fcp:target svc
scsi-fcp:target svc
--> Host finance
--> SVC target N-port
--> SVC target N-port
--> SVC target N-port
--> SVC target N-port
--> SVC target N-port
--> SVC target N-port
--> SVC target N-port
--> SVC target N-port
78-16119-01, Cisco MDS SAN-OS Release 1.3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mds 9500 series