9.3 Core temperature sensor defective (699, 700)

Description The core temperature sensor in the cooking chamber is deactivated.
Location The core temperature sensor is in the front area of the cooking
Naming on the circuit
Troubleshooting Dismount unit cover.
Function check The measurement values can be called up in the status overview.
chamber.
B1
diagram
Check contacting on control board A X24.
Remove existing core temperature sensor from the control board
A1 X24 and plug in new core temperature sensor.
The fault message disappears. Replace core temperature
sensor.
The fault message is still displayed. Replace control board.