Fan Defective Or Temperature Limiter Triggered (702) Only For Compact - Henny Penny 6.10 Service Instructions Manual

Combi steamer
Table of Contents

Advertisement

9.8 Fan defective or temperature limiter triggered (702) only for Compact

Description The control board A1 does not receive any response via the CAN bus
DANGER
Locating errors
cable from fan motor M10. There is an error in the safety circuit or fan
area.
Overview
1 3
c
a Fan motor M10
b Power board T10 for fan motor
Plug assignment power board
Connector X1 (c)
1
L1 230V
2
N
3
PE
Warning: electric shock! Danger of death!
When working on the power board, make sure that energized parts are ex-
posed. Work on these components during operation and up to 3 minutes after
enabling is not allows. Even if the motor is stopped and the appliance is de-en-
ergized, the connection terminals and components can conducted dangerous
voltage!
Location of whether there is an error in the STL circuit (STL =
safety temperature limiter) or in the fan area.
Service instructions
a
d
5
1
b
c Power supply X1
d Connection for fan motor X2
Connector X2 (d)
1
320V DC+
2
Ground
3
15V DC+
4
-
5
PFC
Error messages
51