Canceling the selection Touch the "Back" field.
Relay overview
Relay
Connec-
tor
K1
X10
K1
X11
K2
X11
K3
X12
K4
X12
K5
X12
K6
X12
K8
X17
K17
X12
Dismantling and re-
programming

5.23 Status overview direct access

Description
Touch the "OK" field.
Changes saved.
No.
Description
2
Main contactor Q1
1
POS A
2
POS B
2
Magnetic valve manual rinse
3
Magnetic valve for water vapor
elimination K12
4
Siphon pump G24
5
Backup relay K6
1
Solenoid fresh air M8
1
Circulating pump G16
After changing the control board the original state is restored. Thus,
the backup relay is not used unnecessarily.
Establish the original condition of the wiring (from X12. 5 to Xx).
Calling up the "Backup relay" in the Service menu.
Select "OFF" using the roller.
The backup relay is deactivated.
Touch the "OK" field.
Changes saved.
Direct access in the status overview.
Display of all processes and temperature in ongoing operation.
Service instructions
Service menu - appliance test
Instruction
Reconnect the line from X10.2 to X12.5 and to as-
sign a reserve relay to it.
Reconnect the line from X11.1 to X12.5 and to as-
sign a reserve relay to it.
Reconnect the line from X11.2 to X12.5 and to as-
sign a reserve relay to it.
Reconnect the line from X12. 2 to X12. 5 and to
assign a reserve relay to it.
Reconnect the line from X12.3 to X12.5 and to as-
sign a reserve relay to it.
Reconnect the line from X12.4 to X12.5 and to as-
sign a reserve relay to it.
Reconnect the line from X12.5 to X12.5 and to as-
sign a reserve relay to it.
Reconnect the line from X17.1 to X12.5 and to as-
sign a reserve relay to it.
Reconnect the line from X12.1 to X12.5 and to as-
sign a reserve relay to it.
29