Cooking Chamber Sensor Defective (694, 695) - Henny Penny 6.10 Service Instructions Manual

Combi steamer
Table of Contents

Advertisement

Error messages

9.2 Cooking chamber sensor defective (694, 695)

Description Emergency operation is activated automatically and displayed. The
Location The cooking chamber sensor is in the top right of the cooking
Naming on the circuit
Troubleshooting Dismount unit cover.
Function check The measurement values can be called up in the status overview.
46
core temperature sensor takes over the function of the cooking
chamber sensor. Cooking program with core temperature sensor is
no longer available.
chamber.
B2
diagram
Check contacting on control board A1, X25.
Remove existing cooking chamber sensor from the control board
A1, X25 and plug in new cooking chamber sensor.
The fault message disappears. Replace cooking chamber
sensor.
The fault message is still displayed. Replace control board.