9 Error Messages; Emergency Operation - Henny Penny 6.10 Service Instructions Manual

Combi steamer
Table of Contents

Advertisement

9 Error messages

9.1 Emergency operation

Description In order to allows limited use in case of error, the appliance has
INFORMATION
Overview
Chamber sensor faulty.
Water vapor sensor defective
various emergency programs. Emergency operation is activated
automatically and displayed. After elimination of the error indicated,
the controller switches back into regular operation automatically. A
reset is not necessary.
Emergency programs handle the limited further operation of the appliance until
servicing. Deviating cooking results and temperature deviations are possible.
Error message displayed
Service instructions
Error messages
Description
The core temperature sensor takes over the
function of the cooking chamber sensor.
The software controls the water vapor elimi-
nation. This results in higher water con-
sumption.
45