Power Feed Test Run
The Model G0802 comes with a power feed unit
for X-axis table travel. Proper operation of the limit
switch attached to the front middle of the table is
important to the operation of this power feed unit.
If the power feed does not operate as expected
during the following steps, disconnect it from
power and refer to Troubleshooting on Page 44.
During
power
feed
handwheels spin rapidly when engaged.
Always stay clear of X-axis handwheels
when using power feed. Failure to do so
could lead to entanglement or impact
injuries.
To test run power feed:
1.
Make sure all tools, cables, and other items
are well clear of table movement and potential
direction of travel.
2.
Refer to Operating X-Axis Power Feed
section, beginning on Page 28, to understand
how power feed, table locks, and limit switch
function.
3.
Adjust limit stops to far right and left of table
to allow for maximum table movement in fol-
lowing steps.
4.
Loosen X-axis locks on front of table.
5.
Plug power feed power cord into a grounded
110V power outlet.
6.
Make sure power feed direction lever is in
neutral (middle) position, turn speed dial
counterclockwise to lowest setting, then
move ON/OFF switch to ON position.
-24-
operation,
X-axis
7.
Move direction lever to left, slowly turn speed
dial clockwise to increase speed, then con-
firm that table is moving to left.
8.
Allow table limit stop to hit limit switch
and turn power feed OFF. Table movement
should stop.
— If table movement does not stop,
DISCONNECT POWER IMMEDIATELY
and troubleshoot limit switch.
9.
Move direction lever through neutral (middle)
position and all the way to the right. Table
should begin moving to the right.
10. Repeat Step 7 with table moving to the right.
11. Move direction lever through neutral (middle)
position and all the way to the left, then press
and hold Rapid Traverse button for a few
moments to confirm rapid traverse is operat-
ing correctly. Table should move rapidly to
the left.
12. Release Rapid Traverse Button and move
direction lever to neutral (middle) position.
13. Repeat Steps 11–12 with table moving to the
right.
14. Turn speed dial to lowest setting, and move
ON/OFF switch to OFF position.
Congratulations! The Test Run of the power
feed is complete. Continue to the next
page to perform the Spindle Break-In and
Inspections & Adjustments procedures.