Doc. Ref.No: Q875-0143/ENG
Figure: Reports display showing clear reports question
The figure shows the 'Clear Reports?' question displayed and the default answer
'No'. The '[ ], [ ], [ ], [ ]' keys can all be used to toggle the answer 'No / Yes', and
pressing the [ ] key will confirm the answer. If 'Yes' is chosen then all the stored
reports will be cleared from memory.
9.2.1 Reports Storage Capacity
When the 'printing on demand' mode is set, all reports are stored in a buffer memory
in the metal detector. If the buffer, which has the capability of holding approximately
1200 reports, overflows the oldest reports are discarded and an incident report of
"Messages lost" is entered.
File Name: Q875-0143 ENG Iss2 Met30+ Operating.doc
Issue 2
26/11/04 8:00:15 PRODUCT A S 156 P 68.0
26/11/04 8:02:23 PRODUCT A S 200 P 76.3
26/11/04 8:05:39 product selected [2] PILLS
26/11/04 8:07:48 PILLS S 227 P 130.3
26/11/04 8:07:55 PILLS S 51 P 37.9
26/11/04 8:10:08 PILLS S 221 P 2.1
26/11/04 8:14:21 PILLS S 224 P 3.4
26/11/04 8:18:27 PILLS S 121 P 2.1
Clear Reports? No
26/11/0
4 8:26:50 PILLS S 324 P 0.2
26/11/04 8:28:17 PILLS S 224 P 0.2
26/11/04 8:56:44 test started
26/11/04 8:56:45 operator 1234
26/11/04 8:56:49 test passed
26/11/04 8:57:01 PILLS S 127 P 12.8