Water connection

With separately available guide bars, the rack guide can be converted to the following rack sizes and wall
distances:
Rack size
Distance between the wall and rear of the rack guide
500 x 500 mm
170 mm
530 x 530 mm
155 mm
140 – 150 mm
500 x 500 mm
600 x 400 mm
170 mm
600 x 400 mm
235 mm
14 Water connection
The water-related safety should be as per DIN EN 61770. The machine can be connected to an inlet water supply without an intermedi-
ate connection to other safety equipment.
The machine and any other relevant additional devices must be connected by an authorised specialist company in
relation to local standards and regulations.
Warning

14.1 Requirements for the on-site inlet water connection

Water quality
Water inlet temperature
Water hardness
Minimum flow pressure
Maximum inlet pressure
Rate of flow
14.2 Requirements for the on-site water stop cock
easily accessible
not behind the machine
3/4" connector

14.3 Connecting the supply hose

The supply hose may not be shortened or
damaged.
Old existing hoses may not be re-used.
Caution
Do not bend the supply hose while laying it.
The supply hose and dirt trap are located in the machine.
INFO
The dirt trap prevents particles from the water supply
line entering the machine thus preventing extraneous
rust on the cutlery and in the machine.
Right view
 Connect the supply hose (TWw) to the machine.
 Connect the dirt trap to the on-site water stop cock.
 Connect the supply hose to the dirt trap.
 Open the water stop cock and test whether the connections
are tight.
20
The inlet water must in microbiological aspects have the quality of drinking water
max. 60 °C (80 °C on demand)
max. 50 °C for "effect" version glass washers
 3 °dH (3.8 °e / 5.34 °TH / 0.54 mmol/l ) (recommendation to prevent scaling of the machine)
 30 °dH (37.6 °e / 53.4 °TH / 5.35 mmol/l) for machines with an integral softener
100 kPa (1.0 bar)
600 kPa (6.0 bar)
at least 4 l/min

14.4 Connecting the drain hose

The drain hose may not be shortened or dam-
aged.
Do not bend the drain hose when laying it.
Caution
The drain hose is located in the machine.
INFO
The machine is equipped with a drain pump. The on-
site water drain must have a trap. The maximum height
of the on-site water drain is 650 mm.