A prepared 3U slot in a 19" rack, or other Intermas−compatible enclosure, is required for mount-
ing the A6825 interface card. The slot must be fitted with a 48−pin plug connector (DIN 41612,
design F 48 M). The pin assignment is listed in the following table.
2
UB+ (+ 24V)
4
RS485 bus line 1 A (Port 3) RS485 bus line 1 GND (Port 3) RS485 bus line 1 B (Port 3)
6
not used
8
not used
10 not used
12 RS485 bus line 2 A (Port 4) RS485 bus line 2 GND (Port 4) RS485 bus line 2 B (Port 4) 12
14 RS485 bus line 3 A (Port 5) RS485 bus line 3 GND (Port 5) RS485 bus line 3 B (Port 5) 14
16 RS485 bus line 4 A (Port 6) RS485 bus line 4 GND (Port 6) RS485 bus line 4 B (Port 6) 16
18 RS485 bus line 5 A (Port 7) RS485 bus line 5 GND (Port 7) RS485 bus line 5 B (Port 7) 18
20 RS485 bus line 6 A (Port 8) RS485 bus line 6 GND (Port 8) RS485 bus line 6 B (Port 8) 20
22 not used
24 not used
26 not used
28 not used
30 not used
32 not used
Jumper RS 485
Rs 485 bus operation requires an electrical termination on the first and last bus device.
This is done with plug−in jumpers, on the interface card. The figure shows the position of the
jumpers for the 6 RS 485 bus lines.
d
U− (0V/Common)
not used
not used
not used
not used
not used
not used
not used
not used
not used
b
UN+ (+24V redundant)
not used
not used
not used
not used
not used
not used
not used
not used
not used