SYMPTOM
11. A start time has not been
Watering starts when it should
12. An unwanted program start
not.
Watering does not stop as
13. Programs may have
scheduled.
14. A valve is stuck in the open
26
POSSIBLE CAUSE
entered for the stations
assigned program.
time may have been entered.
accidentally been set to
overlap.
position.
CORRECTION
Turn the dial to PRGM START TIME and
check the start times entered for the
program. If the stations start time is
missing, enter it as described on p.16.
Turn the dial to PRGM START TIME and
check to see if any programs have an
unwanted start time. See the instructions
beginning on p. 16 for setting and deleting
start times.
Check to see if another programs start time
began during the previous programs run
cycle. The overlapped program would
immediately follow the earlier one.
Reprogram if necessary.
Turn the programming dial to OFF and wait
10-20 seconds. If the irrigation does not
stop, shut off the valve manually and repair
the valve.