Siemens SIMOTICS M-1PH818 Operating And Installation Instructions page 245

Main motors
Table of Contents

Advertisement

K3G280-RR04-H9
Siemens AG PD LD Nbg.
4.5 Connection diagram
Drawing preliminary!
No.
Conn.
Designation
1
1, 2
PE
1
3
N
1
5
L
1
6
NC
1
7
COM
2
8
0-10V
2
10
RSB
2
11
RSA
2
12
GND
2
13
+10V
Item no. 55769-5-9970 · ENU · Change 94781 · Approved 2017-09-29 · Page 9 / 12
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
Operating instructions
Color
Function/assignment
green/
Protective earth
yellow
blue
Power supply, neutral conductor, 50/60 Hz
black
Power supply, phase, 50/60 Hz
white 1
Status relay, floating status contact; break for failure, contact rating 250 VAC / 2A (AC1) / min. 10
mA, basic insulation on supply side and reinforced insulation on control interface side
white 2
Status relay, floating status contact; common connection, contact rating 250 VAC / 2A (AC1) / min.
10 mA, basic insulation on supply side and reinforced insulation on control interface side
yellow
Analog input (set value); 0-10 V; Ri = 100 kΩ; adjustable curve
brown
RS485 interface for MODBUS, RSB
white
RS485 interface for MODBUS, RSA
blue
Reference ground for control interface, SELV
red
Fixed voltage output 10 VDC, +10 V ±3%; max. 10 mA; short-circuit-proof; power supply for
external devices (e.g. pot)
245