Chapter III. iWARP

3. Software/Driver Configuration and Fine-tuning

3.1.

Verifying iWARP Functionality

1. Load krping module using the following command:
[root@host~]#
kldload krping
2. Start krping server on one machine as:
[root@host~]#
echo
"verbose,count=5000,server,addr=<chelsioInterface>,port=<port>" >
/dev/krping
3. Start krping client on PEER machine as:
[root@host~]#
echo
"verbose,count=5000,client,addr=<Server_chelsioInterface>,port=<port>" >
/dev/krping
4. After starting the client, read the /dev/krping on server as:
[root@host~]#
cat /dev/krping
krping:num device snd bytes snd msgs rcv bytes rcv msgs wr bytes wr msgs rd bytes rd msgs
krping: 1
listen
Chelsio Unified Wire for FreeBSD
0
0
16
1
60085
70624
917184
0