5.4. Manufacturer's Parameters of N24S
and N25S Meters
Parameter description
Decimal point
Averaging time
Individual
characteristic
Parameter a of the in-
dividual characteristic
Parameter b of the in-
dividual characteristic
Upper overflow of the
measurement
Lower overflow of the
measurement
5.5. Manufacturer's Parameters of N24T
and N25T Meters
Parameter description
Decimal point
Averaging time
Individual
characteristic
Parameter a of the in-
dividual characteristic
Range/value
(N24/N25)
0000, 000.0, 00.00,
0.000/00000, 0000.0,
000.00, 00.000,
0.0000
0.5 s; 1 s; 3 s; 5 s;
10 s; 15 s; 20 s;
disabled, enabled
-19999...9999/
-19999...99999
-19999...9999/
-19999...99999
-1999...9999/
-19999...99999
-19999...9999/
-19999...99999
Range/value
(N24/N25)
0000, 000.0, 00.00,
0.000/00000, 0000.0,
000.00, 00.000,
0.0000
0.5 s; 1 s; 3 s; 5 s;
10 s; 15 s; 20 s;
disabled, enabled
-19999...9999/
-19999...99999
Manufacturer's
value N24S
00.00 for U,I
unipolar;
000.0 for U
bipolar;
1 s
disabled
1
0
9999
-1999
Manufacturer's
value N24T
0000 for J
and K
thermocouples,
000.0 for Pt100
1 s
disabled
1
Table 3
Manufacturer's
value N25S
000.00 for U,I
unipolar;
0000.0 for U
bipolar;
1 s
disabled
1
0
99999
-19999
Table 4
Manufacturer's
value N25T
00000 for J
and K
thermocouples,
0000.0 for Pt100
1 s
disabled
1