Dispenser 1.8: Each dispenser can be activated independently, and the following
parameters must be configured if it is activated:
Start: If dispenser X is active, indicate when this dispenser should start dosing.
Safety level (ML): Start dosing when the safety level is reached.
Level (L): Start dosing when the defined level is reached.
Temperature (T): Start dosing when the defined temperature is reached.
Time: Time, in seconds, of dispenser X. Range can be configured from 0 to 99.
Delay: Delay, in seconds, of dispenser X. From the moment the programme reaches the
start point indicated, the dosing will be delayed for the time indicated. Range can be
configured from 0 to (cycle time-dosing time).
Move while filling: Rotate drum while machine is filling (Yes/No).
Movement while draining: Rotate drum while machine is draining (Yes/No).
Thermal stop: Indicate the moment from which the time stipulated for the cycle is
counted (Yes/No).
Pause programme: This allows you to pause the programme before the cycle in
question starts running. The pause will be indicated on the screen and an acoustic signal is
emitted (Yes/No).
If this parameter is active, before starting the cycle, the machine will go to pause status, and
the message "Pause programmed" is displayed on the screen. To continue running the
programme, press the PLAY button.
3.1.2
Parameters for spin cycles:
Time: Value, in minutes, of the spin length. Range can be configured from 1 to 99.
Speed: Spin speed. There are 4 different speeds to select from: Minimum (1), Normal
(2), Medium (3), Maximum (4).
The Medium (3) and Maximum (4) values are only available in high- and medium-speed
machines respectively.
Please refer to
Untangling: Untangle at the end of the spin cycle (Yes/No).
Optimum distribution: If this option is active, the machine does not drain in the
previous cycle.
Pause programme: This allows you to pause the programme before the cycle in
question starts running. The pause will be indicated on the screen and an acoustic signal is
emitted. (Yes/No).