6 DEDICATED INSTRUCTIONS

6.2 MRECV Instruction

This instruction reads received e-mails.
Set
Internal device
data
Bit
Word
(S)
(D1)
(D2)
[Instruction
[Executing
symbol]
condition]
MRECV
Set data
Set data
Start I/O signal of the local station's Ethernet module.
"Un"
(00 to FE: Higher 2 digits of the 3-digit I/O signal)
(S)
Head device of the local station that stores the control data.
Head device of the local station that stores the contents of the received
(D1)
e-mail (header + attached file).
Local station device that is turned on for one scan by the completion of
(D2)
the instruction.
(D2)+1 is turned on if the instruction execution completes abnormally.
The local devices and the file register for each program cannot be used as devices
used in setting data.
The MRECV instruction can be executed only when the local station is a QCPU.
6 - 2
Applicable device
MELSECNET/H,
MELSECNET/10
File register
Direct J \
Bit
Word
Command
Description
POINT
REMARK
The number of steps for the MRECV instruction is 10.
Special module
Index register Zn
U \G
ZP.MRECV "Un"
(S)
Set by
User
User, system
System
System
MELSEC-Q
Constant
Others
K, H, $
(D1)
(D2)