Electrical Requirements and Wiring Diagrams

Incorrect or improper wiring may result in shock, injury or death. Field wiring to the heater
must be connected and grounded in accordance with national, state, local codes and to the
guidelines in this manual. Refer to the most current revisions to the ANSI/NFPA 70 Standard.
All field wiring to the brooder must be done in accordance with the national, state, provincial, local codes
and the guidelines in this manual. In the United States, refer to the most current revisions to the Electrical
Code ANSI/NFPA 70. In Canada, refer to the most current revisions of the Canadian Electrical Code CSA
C22.1 Part 1. The unit must be electrically grounded according to these codes.
The power supply to the heater must be within +/-5% of the voltage rating as indicated on the rating plate
of the appliance. If input power does not meet these specifications, contact your utility company.
This brooder system is designed to operate on an external 24VAC electrical system. Provide only 24VAC
with a NEC Class 2 transformer to the control wires. Use thermostat type wire that has an adequate capacity
and temperature rating for the total load. Consult to the NEC-90 Standard for sizing wire gauge to load.
3.0
Installation
Electrical Requirements and Wiring Diagrams