Maintaining & Servicing Your Appliance
A. General Maintenance
1. Creosote (Chimney) Cleaning
Frequency: Every 2 months during heating season or
as recommended by a certified chimney sweep; more
frequently if chimney exceeds or is under 1-16 ft (.7
to 4.87m) measured from bottom of appliance.
By: Homeowner / Chimney Sweep
Remove all ash from the firebox and extinguish
Task:
all hot embers before disposal. Allow the appliance to
cool completely. If the chimney has a full reline, remove
the baffle, ceramic blanket and manifold tubes from the
insert before cleaning chimney. Otherwise residue
can pile up on top of the baffle and the appliance will
not work properly. (See Baffle Removal on page 32).
Close the door tightly. The creosote or soot should
be removed with a brush specifically designed for the
type of chimney in use. Clean out fallen ashes from the
firebox.
If the insert is a direct connect within a masonry
chimney, remove the insert from the fireplace. The
creosote or soot can be caught in a large garbage bag
secured to the pipe. Clean any remaining debris from
fireplace smoke shelf.
It is also recommended that before each heating
season the entire system be professionally inspected,
cleaned and repaired if necessary. Close the door
tightly. The creosote or soot should be removed with a
brush specifically designed for the type of chimney in
use. Clean out fallen ashes from the firebox.
If the insert is a direct connect within a masonry
chimney, remove the insert from the fireplace. The
creosote or soot can be caught in a large garbage bag
secured to the pipe.
It is also recommended that before each heating season
the entire system be professionally inspected, cleaned
and repaired if necessary.
Inspection: Inspect the system at the appliance connection
and at the chimney top. Cooler surfaces tend to build creosote
deposits quicker, so it is important to check the chimney from
the top as well as from the bottom.
Formation and Need For Removal: When wood is burned
slowly, it produces tar and other organic vapors which
combine with expelled moisture to form creosote.
The creosote vapors condense in the relatively cool chimney
flue of a newly-started or a slow-burning fire. As a result,
creosote residue accumulates on the flue lining. When
Page 0
5100-I ACT WOOD INSERT
ignited, this creosote creates an extremely hot fire which
may damage the chimney or even destroy the house. The
chimney connector and chimney should be inspected once
every 2 months during the heating season to determine if a
creosote or soot buildup has occurred. If creosote or soot
has accumulated, it should be removed to reduce the risk
of a chimney fire.
3. Disposal of Ashes
Frequency: As necessary
By: Homeowner
Task:
a tight fitting lid. The closed container of ashes should
be placed on a noncombustible floor or on the ground,
well away from all combustible materials, pending final
disposal. If the ashes are disposed of by burial in soil
or otherwise locally dispersed, they should be retained
in the closed container until all cinders have thoroughly
cooled.
438-0380E
WARNING
Fire Risk.
Prevent creosote buildup.
• Inspect chimney connector and chimney
once every two months during heating
season.
• Remove creosote to reduce risk of chimney
fire.
• Ignited creosote is extremely HOT.
Ashes should be placed in a metal container with
WARNING
Risk of Fire
Disposal of Ashes
• Ashes should be placed in metal container
with tight fitting lid.
• Do not place metal container on combustible
surface.
• Ashes should be retained in closed container
until all cinders have thoroughly cooled.
WARNING
Fire Risk.
Do not use chimney cleaners or flame
colorants in your appliance
• Will corrode pipe.
April 21, 2010