R
B. Blower Cord Location
The 5100-I Insert comes standard with  blowers, installed
at the factory with the power cord on right side of insert (as
you face the unit). Do not route the power cord under or in
front of appliance.
The power cord can also be installed on the left side. Follow
instructions below.
Green grounding wire
Black wire into Blue Connector
Left Blower
Snap Disc
Red
Connecto r
Blue
Connector
Figure 12.1 - Blower Assembly Components
Disconnect the appliance from power supply.
1.
2. Remove the grille following instructions on page 11.
. Unplug the blower cord wires from the wire harness.
4. Remove green grounding wire from grounding screw.
5. Using a pair of pliers, squeeze the strain relief and remove
the blower cord wires and strain relief from the grille.
6. Locate the wire harness wires tucked up under the ash-
catcher on the left side of the appliance. Cut the zip tie
that is holding the wires in place.
7. Remove the button plug from the left side of grille. Thread
the blower cords wires through the hole and snap the
strain relief in place. Figure 12.3.
8. Attach grounding wire to ground screw.
9. Connect the white blower cord wire to the red connector
on the wire harness.
10. Connect the black blower cord wire to the blue connec-
tor on the wire harness.
11. Tuck the wire out of the way of the blower motor.
12. Re-install grille.
NOTE: Each wire has a label to denote which
component it connects to.
Page 1
5100-I ACT WOOD INSERT
White wire into Red Connector
Right Blower
Snap Disc
by-pass
switch
Speed Control
(Rheostat)
438-0380E
Blower cord attached to
right side of grille.
White wire
Back view of grille
Figure 12.2
Back view of left
side of grille
Figure 12.3
CAUTION
Shock hazard.
• Do NOT remove grounding prong from plug.
• Plug directly into properly grounded  prong
receptacle.
• Route cord away from appliance.
• Do NOT route cord under or in front
ance.
Strain Relief
Blower cord
Green
grounding wire
Grounding
screw
Black wire
Remove button plug
Grounding screw
April 21, 2010
of appli-

Hide quick links: