Omron NX-ID3343 User Manual page 246

Nx-series digital i/o units machine automation controller
Table of Contents

Advertisement

Appendices
Unit name
DC Input Unit
Number of points
16 points
I/O refreshing method
Switching Synchronous I/O refreshing and Free-Run refreshing
Indicators
TS indicator, input indicators
Dimensions
12 (W) x 100 (H) x 71 (D)
Insulation resistance
20 MΩ min. between isolated circuits (at
100 VDC)
I/O power supply
Supply from the NX bus
method
NX Unit power con-
0.55 W max.
sumption
Weight
65 g max.
Circuit layout
NX bus
connector
(left)
Installation orienta-
Installation orientation: Possible in 6 orientations.
tion and restrictions
Restrictions: No restrictions
Terminal connection
diagram
24 VDC
Disconnec-
Not supported.
tion/Short-circuit
detection
A - 16
Terminal block
IN0 to IN15
I/O power supply +
I/O power supply −
Additional I/O
I/O Power Supply
Power Supply Unit
Connection Unit
A1
B1
A1
IOV
IOV
IOV
IOV
IOG
IOV
IOG
IOV
IOV
IOV
IOV
IOV
IOG
IOG
IOV
IOV
A8
B8
A8
Model
External connection
terminals
Internal I/O common
Rated input voltage
Input current
ON voltage/ON current
OFF voltage/OFF cur-
rent
ON/OFF response time
Input filter time
Isolation method
Dielectric strength
Current capacity of I/O
power supply terminal
Current consumption
from I/O power supply
Current control
circuit
I/O Power Supply
DC Input Unit
Connection Unit
NX-ID5442
B1
A1
B1
A1
IOG
IOG
IN0
IOV
IOV
IOG
IOG
IN2
IOV
IOG
IOG
IN4
IOG
IOG
IN6
IOV
IOV
IOG
IOG
IN8
IN10
IOV
IOG
IOG
IOV
IOG
IOG
IN12
IOV
IOG
IOG
IN14
B8
A8
B8
A8
Protective function
NX-series Digital I/O Unit User's Manual (W521)
NX-ID5442
Screwless clamping terminal block (16 ter-
minals)
PNP
24 VDC (15 to 28.8 VDC)
2.5 mA typical (at 24 VDC), rated current
15 VDC min./2 mA min. (between IOG and
each signal)
5 VDC max./0.5 mA max. (between IOG and
each signal)
20 μs max./400 μs max.
No filter, 0.25 ms, 0.5 ms, 1 ms (default), 2
ms, 4 ms, 8 ms, 16 ms, 32 ms, 64 ms, 128
ms, 256 ms
Photocoupler isolation
510 VAC between isolated circuits for 1
minute at a leakage current of 5 mA max.
Without I/O power supply terminals
No consumption
I/O power supply +
NX bus
connector
I/O power supply −
(right)
Two-wire sensor
B1
IN1
IN3
IN5
Three-wire sensor
IN7
IN9
IN11
IN13
IN15
B8
Not supported.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents