Power Supply - ADS-tec HDT8012 Instruction Manual

Table of Contents

Advertisement

HDT8012

4.2 Power supply

Power is supplied via a 4-pin plug (the figure shows the connector provided in the device).
Pin
1
2
3
4
Recommendation for use:
The power supply must be protected with a 4A fuse (slow-blow).
ATTENTION
Hazard due to damage to device
Damage caused by connected peripherals or data loss
 All cable lines (power supply, interface cables) should only be connected while
the device is switched off and de-energised.
Pos : 18 /D atentec hni k/Inbetri ebnahme/R eihenfolg e der Inbetriebnahme/R ei henfolge der Inbetriebnahme für VMT 60xx- Seri e @ 1\mod_1222073159179_6.doc @ 4100 @ : 19 /D atentec hni k/Inbetriebnahme/Betriebsber eitsc haft prüfen/Betriebsberei tsc haft prüfen für OPC /CPC/PLC/OTC/ITC /VMT- Serie(+M onitor e) / IPC 5100/5500/2400/1100 @ 0\mod_1158905578361_6.doc @ 381 @
ATTENTION
Hazard due to overvoltage
The device can be destroyed by overvoltage.
 Make certain that the permissible voltage values are maintained in
accordance with chapter Technical data.
 Do not operate the device on vehicles that can exceed the permissible
system voltage.
Note on use in accordance with UL-Certification (Underwriter Laboratories):
The device is designed for an LPS supply (Limited Power Source/Class2).
© ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen
Signal
PE
0 VDC
IGN
24 VDC
16

Advertisement

Table of Contents
loading