Dometic MSI912 Installation And Operating Manual page 29

Sine wave inverter. energy & lighting sinepower
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
SinePower
Switching to energy-saving mode
You can set the energy-saving mode using the S4, S5 and S6 dip switches. In this
way, the battery you connect to the inverter is not discharged as quickly.
The inverter operates in energy-saving mode as long as the required power is below
the set level. If the required power exceeds the set level, the inverter works in normal
mode.
The values to be set on your inverter can be found in the following table:
Energy-saving mode
MSI900
Off
70 – 110 W
180 – 240 W
Define settings
You can specify whether the works settings or the settings of the switch S1 – S7
should be used with the dip switch S8
Parameter
Works settings
Use dip switch S1 – S7
Works settings
Mains voltage
230 V
EN
MSI1300
MSI1800
Off
60 – 120 W
110 – 190 W
130 – 170 W
190 – 240 W
180 – 240 W
240 – 300 W
Net frequency
50 Hz
S4
Off
Off
On
On
On
Dip switch
Energy-saving mode
Use inverter
Dip switch
S5
S6
Off
Off
Off
Off
On
Off
On
On
S8
On
Off
Off
29

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents