Air Inlet System, Functional Description - Sullair 3000PB User Manual

40, 50 & 60 hp (30, 37 & 45 kw)
Table of Contents

Advertisement

3000PB, 3700B, 4500B, 3000PVB, 3700VB, 4500VB User Manual
2.7 Air inlet system, functional
description
Refer to Figure 2-6. The compressor inlet system con-
sists of a dry-type air filter, a restriction gauge and an air
inlet valve.
The restriction gauge (located on the air filter) indicates
the condition of the air filter by showing red when filter
maintenance is required.
The poppet-type modulating air inlet valve directly con-
trols the amount of air intake to the compressor in
response to the operation of the pressure regulator.
Refer to Section on page 15. The inlet valve also acts as
a check valve, thus preventing reverse rotation when the
compressor is shut down.
1. Air inlet filter
2. Air inlet
3. Compressor unit
Figure 2-6: Air inlet system
02250216-786 R01
Subject to EAR, ECCN EAR99 and related export control restrictions.
"The Plastic Pipe Institute recommends against
the use of thermoplastic pipe to transport com-
pressed air or other compressed gases in
exposed above ground locations, e.g. in exposed
1
plant piping."
®
Sullube
should not be used with PVC piping sys-
tems. It may affect the bond at cemented joints.
Certain other plastic materials may also be
affected.
1
Plastic Pipe Institute, Recommendation B. Adopted
January 19, 1972.
4. Separator/sump tank
5. Restriction indicator
2: Description
WARNING
17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

3700b4500b4500vb3000pvb3700vb

Table of Contents