APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 34 of 57)
ADDR
REGISTER NAME
IEC 61850 received analog settings (read/write)
AA00
IEC 61850 GOOSE analog 1 default value
AA02
IEC 61850 GOOSE analog input 1 mode
AA03
IEC 61850 GOOSE analog input 1 units
AA05
IEC 61850 GOOSE analog input 1 per-unit base
AA07
...Repeated for IEC 61850 GOOSE analog input 2
AA0E
...Repeated for IEC 61850 GOOSE analog input 3
AA15
...Repeated for IEC 61850 GOOSE analog input 4
AA1C
...Repeated for IEC 61850 GOOSE analog input 5
AA23
...Repeated for IEC 61850 GOOSE analog input 6
AA2A
...Repeated for IEC 61850 GOOSE analog input 7
AA31
...Repeated for IEC 61850 GOOSE analog input 8
AA38
...Repeated for IEC 61850 GOOSE analog input 9
AA3F
...Repeated for IEC 61850 GOOSE analog input 10
AA46
...Repeated for IEC 61850 GOOSE analog input 11
AA4D
...Repeated for IEC 61850 GOOSE analog input 12
AA54
...Repeated for IEC 61850 GOOSE analog input 13
AA5B
...Repeated for IEC 61850 GOOSE analog input 14
AA62
...Repeated for IEC 61850 GOOSE analog input 15
AA69
...Repeated for IEC 61850 GOOSE analog input 16
IEC 61850 XCBR configuration (read/write settings)
AB24
Operand for IEC 61850 XCBR1.ST.Loc status
AB25
Command to clear XCBR1 OpCnt (operation counter)
AB26
Operand for IEC 61850 XCBR2.ST.Loc status
AB27
Command to clear XCBR2 OpCnt (operation counter)
AB28
Operand for IEC 61850 XCBR3.ST.Loc status
AB29
Command to clear XCBR3 OpCnt (operation counter)
AB2A
Operand for IEC 61850 XCBR4.ST.Loc status
AB2B
Command to clear XCBR4 OpCnt (operation counter)
AB2C
Operand for IEC 61850 XCBR5.ST.Loc status
AB2D
Command to clear XCBR5 OpCnt (operation counter)
AB2E
Operand for IEC 61850 XCBR6.ST.Loc status
AB2F
Command to clear XCBR6 OpCnt (operation counter)
IEC 61850 LN name prefixes (read/write settings)
AB30
IEC 61850 logical node LPHD1 name prefix
AB33
IEC 61850 logical node PIOCx name prefix (72 items)
AC0B
IEC 61850 logical node PTOCx name prefix (24 items)
AC53
IEC 61850 logical node PTUVx name prefix (13 items)
AC7A
IEC 61850 logical node PTOVx name prefix (10 items)
AC98
IEC 61850 logical node PDISx name prefix (10 items)
ACB6
IEC 61850 logical node RBRFx name prefix (24 items)
ACFE
IEC 61850 logical node RPSBx name prefix
AD01
IEC 61850 logical node RRECx name prefix (6 items)
AD13
IEC 61850 logical node MMXUx name prefix (6 items)
AD25
IEC 61850 logical node GGIOx name prefix (5 items)
AD34
IEC 61850 logical node RFLOx name prefix (5 items)
AD43
IEC 61850 logical node XCBRx name prefix (6 items)
AD55
IEC 61850 logical node PTRCx name prefix (6 items)
AD67
IEC 61850 logical node PDIFx name prefix (6 items)
AD73
IEC 61850 logical node MMXNx name prefix (6 items)
ADE2
IEC 61850 logical node CSWIx name prefix (6 items)
AE3C
IEC 61850 logical node XSWIx name prefix (6 items)
IEC 61850 XSWI configuration (read/write settings)
AECF
Operand for IEC 61850 XSWI1.ST.Loc status
GE Multilin
N60 Network Stability and Synchrophasor Measurement System
RANGE
UNITS
–1000000 to 1000000
---
0 to 1
---
---
---
0 to 999999999.999
---
0 to 65535
---
0 to 1
---
0 to 65535
---
0 to 1
---
0 to 65535
---
0 to 1
---
0 to 65535
---
0 to 1
---
0 to 65535
---
0 to 1
---
0 to 65535
---
0 to 1
---
0 to 65534
---
0 to 65534
---
0 to 65534
---
0 to 65534
---
0 to 65534
---
0 to 65534
---
0 to 65534
---
0 to 65534
---
0 to 65534
---
0 to 65534
---
0 to 65534
---
0 to 65534
---
0 to 65534
---
0 to 65534
---
0 to 65534
---
0 to 65534
---
0 to 65534
---
0 to 65534
---
0 to 65535
---
B.4 MEMORY MAPPING
STEP
FORMAT
DEFAULT
0.001
F060
1000
1
F491
0 (Default Value)
---
F207
(none)
0.001
F060
1
1
F300
0
1
F126
0 (No)
1
F300
0
1
F126
0 (No)
1
F300
0
1
F126
0 (No)
1
F300
0
1
F126
0 (No)
1
F300
0
1
F126
0 (No)
1
F300
0
1
F126
0 (No)
1
F206
(none)
1
F206
(none)
1
F206
(none)
1
F206
(none)
1
F206
(none)
1
F206
(none)
1
F206
(none)
1
F206
(none)
1
F206
(none)
1
F206
(none)
1
F206
(none)
1
F206
(none)
1
F206
(none)
1
F206
(none)
1
F206
(none)
1
F206
(none)
1
F206
(none)
1
F206
(none)
1
F300
0
B