Troubleshooting; Specifications - Olimpia splendid Unico Boiler Instructions For Installation, Use And Maintenance Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 35
3
3.5.2

Troubleshooting

In case of malfunctions, check the following table.
If the problem persists after the suggested checks and controls, contact the authorised technical service.
FAULTS
The unit does not turn on
The unit does not cool or
heat adequately
Resetting the bipolar safety thermostat (ref. D fig. 35)
In the event the water heating up abnormally, a thermal safety switch conforming to CEI standards interrupts the
electrical circuit on both phases supplying the heating element with power; if this happens seek the intervention of
Service Assistance.
3.5.3

Specifications

For the technical data listed below, consult the characteristic data plate applied to the product
- Power supply voltage
- Maximum power absorbed
- Maximum current absorbed
- Coolant gas
- Protection rating of the containers
- Max working pressure
Dimensions (W x H x D)
Weight (without packing)
Maximum operating temperature in cooling mode
Minimum operating temperature in cooling mode
Maximum operating temperatures in heating
Minimum operating temperatures in heating
COOLANT PIPELINE (not supplied)
- Diameter of liquid line connecting pipes 6.35 mm (1/4")
- Diameter of gas line connecting pipe 9.52 mm (3/8")
- Maximum length of connecting pipeline 10 m
- Maximum height difference between internal and external unit 5 m
- Communication cable
- UNICO BOILER WALL power supply cable
WATER TANK CAPACITY 50 LITRES
MAXIMUM WORKING PRESSURE ON WATER SIDE FOR UNICO BOILER MASTER PS 600 kPa (0.6 MPa)
54
POSSIBLE CAUSES
• No power supply
• The power switch is in "0" position
• Remote control batteries are flat
• The temperature set on the remote control is either
too high or too low (when using the
heating pump unit).
• The air filter has been blocked before the
respective cleaning LED was switched on.
• Indoor or outdoor air flow obstacles are present.
• The heating/cooling load has increased (for example
a door or a window was left open or equipment that
dissipates a large amount of heat was installed in the
same room);
• Both the internal units are running; the heating load is
greater than the power of each internal unit.
OPERATIONAL LIMITS
• Check that mains power is present (by turning on
• Check if the master switch is closed or if a fuse
• Move the power switch to "1" position (fig. 42 ref.
• If the batteries are flat, you will notice that no
• Check the temperature setting on the remote
• Check the air filter and clean it if necessary.
• Remove anything that might clog the air flows.
• Switch off one of the two internal units.
UNICO BOILER MASTER
mm 902x516x229
kg 40
Internal ambient temp.
DB 35°C - WB 24°C
DB 18°C
DB 27°C
-
SUPPLY CABLES:
2 x 0.5 mm2 screened, maximum length 15 m
H05VV-F 3 x 1,5 mm
2
SOLUTIONS
a light for instance).
is burnt (in this case replace the fuse). If there is
a magnetothermal circuit breaker instead of the
master switch, check if it tripped (if it did, rearm
it). Should the problem occur again, contact the
Service Center at once and do not attempt to run
the unit.
A).
messages are displayed and that the unit's
reception confirmation sound is missing when
you try to issue any command to it. In this case
replace the batteries.
control and correct it if need be.
UNICO BOILER WALL
mm 760x253x190
kg 8
Outside ambient temp.
DB 43°C - WB 32°C
DB -10°C
DB 24°C - WB 18°C
DB -15°C

Advertisement

Table of Contents
loading

Table of Contents