STEAM GENERATOR
STN-30-1/2
STN-50-1/2
STN-35-1/2
STN-40-1/2
STN-45-1/2
Congratulations on your purchase of a SAWO Steam Generator.
Please read the manual carefully before using the steam generator.
4,5 kW
3,0 kW
3,5 kW
5,0 kW
4,0 kW
9,0 kW
12,0 kW
15,0 kW
STN-45-3
STN-75-3
STN-45-C1/3
STN-75-3-C1/3
STN-60-3
STN-60-C1/3
4,5 kW
6,0 kW
7,5 kW
ENGLISH
MANUAL
STN-90-3
STN-90-C1/3
STN-120-3
STN-150-3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the STN-30-1/2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Sawo STN-30-1/2

  • Page 1 STN-75-3-C1/3 STN-90-C1/3 STN-40-1/2 STN-60-3 STN-120-3 STN-45-1/2 STN-60-C1/3 STN-150-3 Congratulations on your purchase of a SAWO Steam Generator. Please read the manual carefully before using the steam generator. 4,5 kW 3,0 kW 4,5 kW 3,5 kW 5,0 kW 6,0 kW 4,0 kW...
  • Page 2: Table Of Contents

    Electrical Diagram ..............15 Installing the Temperature Sensor ........... 18 Installing Control Unit ............19 Connection of SAWO Control to the PCB ........20 Terminal Connection of Demand Button (optional)....21 DIP switches in the steam Generator ........22 Steam Generator Series Connection ........23 Troubleshooting ...............
  • Page 3: Before Installation

    Ensure that the steam generator kilowatt corresponds to the volume of your steam room. Refer to Technical Data (See page 15). WaRnInG! The voltage of the light output is 230VAC. Sawo recommends to use less than 50V for the steam room lightning. Use appropriate transformer for lower voltages.
  • Page 4: Steam Generator Parts

    steam Generator Parts For illustrative purposes only. Terminal for Water Level Probe steam generator Contactor accessories Transformer Power switch Steam Outlet Over Pressure Valve Autodrain Alternative Drain outlet WaRnInG! For illustrative purposes only. Not for use for wiring. For component identification only. ENGLISH...
  • Page 5: Instructions Of Use

    Instructions of Use There are four different operation modes in the unit: Off, On, Standby and Drain. The user can easily switch between different modes, making the steam bathing more conve- nient with less energy consumption. To use steam room the control unit needs to be in the On mode. In the On mode, the steamer is active, the temperature in the steam room will be kept in the preferred, set temperature, with occasional discharge of steam.
  • Page 6: Standby Mode

    standby Mode During the standby-mode the water in the steam generator tank is kept hot. This mini- mizes the time to produce steam when generator goes to on-mode next time. Standby-mode can be activated by any of the following methods when the unit is in on- mode: 1.
  • Page 7: Key Lock

    Key lock Lock and unlock the key pad by pressing the up and down buttons at the same time for more than 5 seconds. A high beep will confirm the activation and the deactivation. Only On/Off, Standby and Cabin light buttons are usable when the key pad is locked.
  • Page 8: Scent Pump

    scent Pump Before switching scent pump on make sure there is enough aroma in the aroma container. Never run the scent pump dry. Scent pump can be operated in “On” mode only. In order to switch scent pump on/off short press “Fan/Scent” button. The Scent pump is allowed to be turned on only when the water in the tank is boiling.
  • Page 9: Maintenance

    They are connected to the water source of the steam generator’s water inlet. SAWO Decalcifying Solution can be used for decalcification. Follow these guidelines to perform preventative maintenance of the steam generator.
  • Page 10: Level Probe Cleaning

    level probe cleaning c. Disconnect steam generator from main supply before opening generator’s covers. Only licensed electrician or professional maintenance person can open covers and do cleaning. d. Use adjustable wrench to deattach 3 wires from level probe. Make sure that when connecting wires back, wires are connected to right probes.
  • Page 11: Assembly And Installation

    assembly and Installation 1. Location of the steam generator has to be near the steam room. Place it within 7.5 meters to the steam room. 2. Steam generator has to be installed outside the steam room. 3. The steam generator must not be installed outdoors or areas that may damage the unit due to climate conditions.
  • Page 12: Steam Generator

    steam Generator 3,0 kW | 3,5 kW | 4,0 kW | 4,5 kW | 5,0 kW Side view noTe! showing element 4,5 kW | 5,0 kW | 6,0 kW |7,5 kW If facing the wall there should be access panel at least 100mm allowance.
  • Page 13: Steam Outlet

    steam outlet The steam must move in a continuous flow to the steam room. Do not install valves on the steam line. Use insulated, rated 120ºC or higher, brass pipe or copper tubing for steam line to connect to the steam head as permitted by codes (see table below). Slope the steam line height by 20mm per meter towards the steam head to avoid trapping of the condensate and eliminate steam trap that blocks the flow of the steam.
  • Page 14: Drain

    Use two-wire supply source and equipment grounding wire of single phase connection. A 90ºC / 600V (HO7RN-F) rated insulated copper wire is required for SAWO steam generators. Check size of wires in Ampere Chart in accordance with the National Electrical Code and local electrical code.
  • Page 15: Technical Data

    Volume Type Width Depth Height (m³) (kW) Number mm² (mm) (kg) STN-30-1/2 3 max 2 x 1,5 kW STG-150 220 - 240 / 1N / 380 - 415 STN-35-1/2 3,5 max 1 x 1,5 kW STG-150 220 - 240 /...
  • Page 16 4,5 kW |6,0 kW | 7,5 kW ConVeRTIble 380-415V TRANSFORMER 5 core cable WATER FEED SOLENOID VALVE 4 core cable 24VAC IN CONT. DRAIN FILL 220-240V PROBE1 230VAC in PROBE2 PROBE3 FUSE GROUND CONTROL NTC2 TEMP BOARD 3 core cable 220-240V SCENT PUMP SWITCH...
  • Page 17 9,0 kW ConVeRTIble 380-415V TRANSFORMER 5 core cable WATER FEED 220-240V SOLENOID VALVE 24VAC IN CONT. DRAIN FILL 4 core cable PROBE1 230VAC in PROBE2 220-240V PROBE3 FUSE GROUND CONTROL NTC2 TEMP BOARD SCENT PUMP 3 core cable SWITCH LIGHT 4 meters NTC2 FUSE...
  • Page 18: Installing The Temperature Sensor

    The temperature sensor comes along with the SAWO steam generator. It is recommended to use only Sawo temperature sensor with Sawo generator as it may otherwise not function correctly.Temperature sensor wiring should not be routed near power cables or hot areas as it may cause electronic interference or damage to the wires.
  • Page 19: Installing Control Unit

    Installing Control Unit SAWO Steam Control sets the temperature of your steam room. Mount the steam control unit on an accessible area outside the steam room. It is recommended not to place the steam control near to showers or similar wet places.
  • Page 20: Connection Of Sawo Control To The Pcb

    Connection of saWo Control to the PCb Before installation make sure that the generator is disconnected from the mains by switching off the circuit breaker. 1. Unscrew PCB cover on the side of the generator to get access on the PCB.
  • Page 21: Terminal Connection Of Demand Button (Optional)

    Terminal Connection of Demand button (optional) Before installation make sure that the mains is Terminal Block disconnected from the generator by turning off the circuit breaker. 1. Open the top cover of the generator. 2. Guide the cable through cable lead-in on the side of the generator.
  • Page 22: Dip Switches In The Steam Generator

    DIP switches in the steam Generator fIRsT bloCK seConD bloCK STAND-BY ON/OFF standby time session Time Standby time can be set according to Session time can be set according to user preferences by setting dip switches user preferences by session dip switch- on the power controller board es on the power controller board.
  • Page 23: Steam Generator Series Connection

    steam Generator series Connection Steam Generator Master Slave 1 Slave 2 Slave 3 Slave 4 Control Steam Generator Steam Generator Steam Generator DIP SW DIP SW DIP SW RJ12 Cable 3 = OFF 3 = ON 3 = ON 2 = OFF 2 = ON 1 = OFF 1 = OFF...
  • Page 24 No master steam Dip switch setting is incorrect. Check dip generator connected. switch settings. Check RJ12 for loose contact. Replace RJ12. If no problem can be found, contact the retailer. Pidätämme oikeuden muutoksiin. Subject to change without notice. www.sawo.com | info@sawo.com...