before Installing
Use the following information together with the consultation of your contractor, architect
or designer in determining all factors necessary in providing a suitable and safe steam
room.
Check that the supply voltage is suitable to your steam generator.
Ensure that the steam generator kilowatt corresponds to the volume of your steam
room. Refer to Technical Data (See page 15).

steam Room Guidelines

1. The Steam Room must be fully enclosed, complete with walls, door, flooring and
ceiling.
2. Rubber linings (e.g. gaskets) are recommended for the door to effectively seal the
heat and the steam inside the Steam Room.
3. If tiles are used for the flooring or some other smooth surface material, provide
suitable anti-skid strips or rubberized mats to prevent slipping resulting to injury.
4. Materials used for the walls and ceiling should have water-resistant, non-corrosive
surfaces such as tiles, marbles, molded acrylic, or other non-porous materials. The
ceiling should be dome-shaped to prevent the dripping of condensate.
5. A drain must be provided in the flooring.
6. Heating, venting or air conditioning devices should not be installed inside the Steam
Room.
7. Steam Room windows should be double paned.
8. Limit the Steam Room ceiling to a height of 2,5 meters. Exceeding 2,5m will require
a higher-rated steam generator.
9. Floor drain for the steam generator must be available for maintenance.
WaRnInG!
The voltage of the light output is 230VAC. Sawo
recommends to use less than 50V for the steam
room lightning. Use appropriate
for lower voltages. Sawo is not responsible of
damages caused by using higher voltage inside
the steam room.