SM3000
3 DESCRIPTIONS
OUT PUT
1)
The SM15-200D, SM30-100D, SM45-70D,
SM70-45D, SM120-25D and SM300-10D
can ei ther be used as a con stant volt age
source with cur rent lim it ing or as a con stant
cur rent source with volt age lim it ing.
The change of mode oc curs sharply at the
cross ing of the volt age and cur rent set tings
(fig. 3 - 1 shows the out put ranges).
DIS PLAY CV/CC SETTING FUNCTION
°
The set ting of the volt age and cur rent con -
trol can be ob served on the front panel me -
ters by press ing the Dis play CV/CC Set ting
but ton. This al lows the cur rent limit to be set
when op er at ing in the CV mode with out
short ing the out put ter mi nals, and the volt -
age limit to be set when op er at ing in the CC
mode with out open ing the load leads.
OVER LOAD PRO TEC TION
°
The power sup ply is fully pro tected against
all over load con di tions, in clud ing short cir -
cuit.
IN PUT VOLT AGE
2)
The power sup plies have a wide in put volt -
age range.
The units need a 3 phase in put volt age,
°
but no neu tral con nec tion is re quired.
The units can also op er ate on one phase
°
but at 90% of the max. out put volt age,
with a slight in crease of the out put rip ple
volt age.
The units can also be used as a DC/DC
°
con verter.
non-standard line in put volt age
°
The units will still op er ate at a line in put
volt age lower than stan dard, but with a re -
duc tion in out put power. Figure 3 - 3
shows the max. out put cur rent as a func -
tion of out put volt age with AC or DC line
in put volt age as a pa ram e ter.
Ex am ple: Say the re quired out put volt age
is 24 V at a line in put volt age of 270 V AC.
Figure 3 - 2 shows the max i mum out put
cur rent for the SM30-100D to be 59 A.
Note: All AC in put curves are mea sured
°
us ing 3 phase in put.
IN PUT CUR RENT
3)
fig. 3 - 2
Ex am ple how to use the graph
rev. February 2018
SM 15-200 D
SM 30-100 D SM 45-70 D
ev ery point in hatched area can be used
Max. out put cur rent vs out put volt age
with AC or DC line in put volt age as a pa ram e ter
DELTA ELEKTRONIKA B.V.
SM 120-25 D
SM 70-45 D
fig. 3 - 1
The out put ranges.
fig. 3 - 3
DESCRIPTIONS
SM 300-10 D
Page 3 - 1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sm300-10dSm45-70dSm30-100dSm70-45dSm120-25d

Table of Contents