Delta Elektronika SM15-200D Product Manual page 18

Sm 3000 series, programmable
Table of Contents

Advertisement

SM3000
OUT PUT VOLT AGE IS HIGHER THAN SET VALUE
7)
Check con nec tions on SENSE BLOCK (on rear panel), For nor -
mal op er a tion there should be a link be tween + and S+ and be -
tween – and S– (see also fig. 4 - 18). When re mote sens ing is
used, check the wires of the sens ing.
OVP LED on.
8)
Check OVP set ting.
Over heating also causes the OVP led to be on, cool ing down will
re set the ther mal pro tec tion.
You are us ing Re mote Sensing.
Even a short volt age pulse >3V be tween – and S – causes the
OVP cir cuit to limit the out put volt age.
Re mote ShutDown volt age is ap plied to the prog. con nec tor.
NO LEDS on.
9)
Over heating can be the cause, cool ing down will re set the ther mal
pro tec tion.
Check in put power and in put fuses (on rear panel)
Check fuses F400 and F401 on P430, a blown fuse can be
caused by a de fec tive rec ti fier bridge D400 or D401. Note: The
fuses are of a spe cial 500 V type.
The aux il iary power sup ply (board P430) is de fect. Do not try to re -
pair P430 (ex cept for D400, D401, F400 and F401), but send
P430 for re pair or ask for re place ment.
CHECK POINTS IN CASE OF A SE RI OUS FAIL URE
10)
No Out put
No LED on
The unit is not
over heated
Check fuses on
rear panel
Re place P430,
see 8)
Check out put di odes.
De fec tive di odes give a short.
SM 15-200 D Check di odes D300 - D315
SM 30-100 D Check di odes D300 - D309
SM 70-45 D
Check di odes D300 - D303 on P457
SM 120-25 D Check di odes D300 - D303 on P458
Re place de fec tive parts.
Fuse F200 and / or F201 on P428 are blown.
Prob a bly there is a de fect on one of the two boards P433.
First check out put di odes, see above.
WARNING: Do not re place F200 or F201until the unit is re paired.
Re placing fuse F200 and F201 while P433 is still de fect will cause
R104 till R109 to blow, this will dam age the board P428.
Note: Do not try to re pair P433, but send the sub unit with 2x P433
for re pair or ask for re place ment.
Pref er a bly con sult fac tory when you dis cover a de fect in P433.
rev. February 2018
One or mor e
LEDs on
Check fuse F200,
F201 on P428
O.K.
Blown
Pro ceed with
Pro ceed with
sec tion: Check
sec tion: Fuse
out put di odes
F200, F201 is
blown see 9).
DELTA ELEKTRONIKA B.V.
OPERATING - TROUBLE SHOOTING - CALIBRATING
fig. 4 - 18
For nor mal op er a tion links should be con nected
be tween S+ and + and be tween S– and –
Page 4 - 7