4.13
Battery care
If the battery is still dry, it must be activated as described in section 4.13.2 Activating a dry-
charged battery.
The battery must be in operation within 2 months from being activated; if not, it needs to be
recharged first.
4.13.1
Electrolyte
Electrolyte in batteries is a sulphuric acid solution in distilled water.
The solution must be made up before being introduced into the battery.
4.13.2
Activating a dry-charged battery
Take out the battery.
•
Battery and electrolyte must be at equal temperature above 10 °C (50 °F).
•
•
Remove cover and/or plug from each cell.
Fill each cell with electrolyte until the level reaches the mark on the battery. If there is no mark
•
on the battery, the level must be above the plates for at least 10 mm (0.4 in) to 15 mm (0.6 in).
•
Rock the battery a few times so that possible air bubbles can escape; wait 10 minutes and
check the level in each cell once more; if required, add electrolyte.
Refit plugs and/or cover.
•
Place the battery in the compressor.
•
74
Before handling batteries, read the relevant safety precautions and act
accordingly.
Read the safety instructions carefully.
Always pour the sulphuric acid carefully into the distilled water; never pour the
water into the acid.
Instruction Manual
2954 2510 03