The 615BPR automated system consists of an aluminium
beam with reflex reflectors, and a steel upright subjected
to cataphoresis treatment and painted with polyester paint.
The upright houses the hydraulic operator and the electronic
control unit.
The operator, which moves the beam, consists of a hydraulic
power pack and a double-acting cylinder.
The system is supplied with an adjustable torque limitation
system. It also includes a device stopping the beam in any
position, and a handy manual release command for use in
case of power cuts or faults.
The beam and the relevant balancing spring must be ordered
by referring to the sales price list.
The 615BPR automated system was designed and built
for controlling vehicle access. Do not use for any other
purpose.

1 DESCRIPTION AND TECHNICAL SPECIFICATIONS

foundation plate
barrier upright
control board
emergency release
torque adjustment screws
double acting piston
travel limit screw
M12 nut blocking the tie
rod
AUTOMATED SYSTEM 615BPR
fig.1
rocker
oil filling plug
breather screw
balancing spring
spring adjustment tie-rod
hydraulic power pack
travel limit sensors
travel limit magnets
3
Tab. 1 - Technical specifications "Barrier 615BPR"
BARRIER MODEL
Beam max. length (m)
Max. opening time (sec)
Angular speed (rad/sec)
Pump flow-rate (l/min)
Max. torque (Nm)
Types of beam
Use frequency (at 20°C)
Max. consecutive cycles (at 20°C)
Power supply
Absorbed power (W)
Type of oil
Oil quantity (Kg)
Thermal protection for winding
Torque adjustment system
Operating ambient temperature
Hood protective treatment
Hood paint
Protection class
Weight (Kg)
Upright dimensions LxHxP(mm)
Electric motor technical specifications
RPM
Power (W)
Absorbed current (A)
Power supply

1.1 MAXIMUM USE CURVE

The curve makes it possible to establish maximum work time (T)
according to use frequency (F).
E.g. The 615 BPR automated system can operate non-stop at a use
frequency of 50%.
To ensure efficient operation, operate in the work range under the
curve.
Important: The curve is obtained at a temperature of 20 °C. Exposure
to the direct sun rays can reduce use frequency down to 20%.
Calculation of use frequency
The percentage of effective work time (opening + closing) compared
to total time of cycle (opening + closing + pause times).
Calculation formula:
Ta + Tc
%F =
X 100
Ta + Tc + Tp + Ti
where:
Ta = opening time
Tc = closing time
Tp = pause time
Ti = interval time between
one complete cycle and
another.
615BPR STD
615BPR RAP
5
2,5
5,7
2,9
0.28
0,54
1.5
3
400
300
Rectangular / Rectangular
skirt articulated / Round
50%
40%
220
340
230V~ (+6 -10 %) 50Hz
220
FAAC HP OIL
0,9
120° C
standard by-pass valves
-40 ÷ +55 °C
cataphoresis
Polyester RAL 2004
IP 44
34
270 x 1015 x 140
1400
2800
220
1
230V~ (+6 -10 %) 50Hz
10