FAAC DSW2000 Instructions For Use Manual

FAAC DSW2000 Instructions For Use Manual

Swing gate operator

Advertisement

Quick Links

DSW2000
Swing Gate Operator
FAAC International Inc.
FAAC International Inc.
Headquarter & East Coast Operations
West Coast Operations
5151 Sunbeam Road #9-11
357 S Acacia Avenue #357
Jacksonville, FL 32257
Fullerton, CA 92831
American Built
(866) 925-3222
(800) 221-8278
www.FAACUSA.com
Revision D

Advertisement

Table of Contents
loading

Summary of Contents for FAAC DSW2000

  • Page 1 DSW2000 Swing Gate Operator FAAC International Inc. FAAC International Inc. Headquarter & East Coast Operations West Coast Operations 5151 Sunbeam Road #9-11 357 S Acacia Avenue #357 Jacksonville, FL 32257 Fullerton, CA 92831 American Built (866) 925-3222 (800) 221-8278 www.FAACUSA.com...
  • Page 2: Table Of Contents

    Read and follow all U.L. and Safety Standards before installing any access device. Please refer to this manual and qualified personnel for assistance. Do not install this device unless all entrapment and pinch points are eliminated! DSW2000 Swing Gate Operator...
  • Page 3: Important User Instructions

    Proper reversing devices MUST be installed on all gates to avoid all potential hazards and entrapment. 9. SAVE THESE INSTRUCTIONS DSW2000 Swing Gate Operator...
  • Page 4 Fence Vehicular Gate Only Building Structure Provide spacing between the hinge, gate Fence and building to reduce the risk of entrapment in this area Mount hinges on the corner of pilasters to help prevent entrapment areas. DSW2000 Swing Gate Operator...
  • Page 5: Internal Entrapment Prevention

    CAUTION: This beam only detects at the installed height. One or more Edge Sensors shall be Bottom Edge located on the inside and outside Sensor If Greater leading edge of the gate. Than 6 Inches DSW2000 Swing Gate Operator...
  • Page 6: Manual Release

    Travel Speed ................90 Degrees In Approx 14 Seconds Maximum Gate Weight ............. 750 lbs Maximum Gate Length .............. 18 Feet Primary Entrapment Protection ..........Inherent Current Sensor Secondary Entrapment Protection ..........Provisions for Non-Contact & Contact Sensors DSW2000 Swing Gate Operator...
  • Page 7: Ul325 Gate Operator Classification

    CONTACT SENSOR: External device such as a edge sensor used to provide entrapment prevention located where a risk of entrapment or obstruction exists such as the leading edge, trailing edge, and posts mounted inside and outside of the vehicular slide gate and motor. DSW2000 Swing Gate Operator...
  • Page 8: Warning Sign Installation

     Select the proper gate operator for the installation. Consider the usage, capacity, gate size, gate weight, and needed features and safety accessories.  If proper safety guidelines can not be followed. Do not install this gate operator or place the operator into service. DSW2000 Swing Gate Operator...
  • Page 9: Gate Operator Location

    ONCRETE OCATION The DSW2000 vehicular gate operator is designed to be mounted on a concrete pad. Select a location for the gate operator to be installed. For pad location and size: 1. Determine the location for the operator to be installed. Determine the location of the output shaft as described above. The concrete pad will be 12”...
  • Page 10: Ate Perator Nstallation

    4. Move the Release Handle down to tighten. 5. The Release Handle Nut Plate may be removed to adjust the Release Handle position if needed. Reconnect the plate when adjusted. 6. Attach the top Arm Cap Cover. DSW2000 Swing Gate Operator...
  • Page 11: Limit Switch Setup

    3. If the gate opens to the LEFT, move DIP SWITCH 6 to the Left. 4. If the gate opens to the RIGHT, move DIP SWITCH 6 to the Right. Opens LEFT Opens RIGHT Switch 6: Switch 6: DSW2000 Swing Gate Operator...
  • Page 12: Lectrical Nstallation

    3. Connect the AC input wires to the AC terminal located on the bottom/center of the control box. See diagram below. 4. Batteries must be installed after the AC power is on. See Battery Power Connection. GREEN = Ground WHITE = Neutral BLACK = 120 VAC DSW2000 Swing Gate Operator...
  • Page 13: Battery Power Connection

    Additional 24 VDC for accessories may be found on the Radio Terminal, Edge/Photo Terminal, and External Loop Terminal. A connection between 24V DC+ and Common will supply power. DSW2000 Swing Gate Operator...
  • Page 14: Master/Slave Connection

    MASTER GREEN to SLAVE GREEN (Pin 6 to Pin 1)  MASTER BROWN-WHITE to SLAVE BROWN-WHITE (Pin 5 to Pin 5)  Slave Gate Operator Slave Plug Slave Switch 3: Master Plug Master Gate Operator Master Switch 3: DSW2000 Swing Gate Operator...
  • Page 15: Ate Perator Djustments

    4. Only resetting the operator will reactivate the gate and return it to normal operation. 5. To reset the operator in a Hard Shut Down situation: Press the reset button on the left side of the controller or turn the power switch OFF and back ON. DSW2000 Swing Gate Operator...
  • Page 16: Close Time Delay Adjustment

    Delays 2 seconds before activating gate. Allows time for maglock to discharge. OFF: No action - not used on DSW2000 Option 1 - Tamper Det Activates Tamper Detect Feature - not used on DSW2000 OFF: Normal Soft Start, Soft Stop mode. Option 2 - Hard Start Activates Hard Start Mode.
  • Page 17: Accessory Connections

    CCESSORY ONNECTIONS CCESSORY ONNECTIONS CCESSORY VERVIEW FIRE LOCK Card Access Phone Entry CLOSE Photo Cell Key Box OPEN STOP Photo Cell CLOSE Radio Receiver OPEN DSW2000 Swing Gate Operator...
  • Page 18: Edge Sensor Connections

    All wireless contact sensors shall function under the intended end-use conditions. Wireless contact sensors should be checked on a regular basis. Batteries should be replaced on a regular basis. DSW2000 Swing Gate Operator...
  • Page 19: Photo Sensor Connections

    Refer to the diagrams in the “Important Safety Information” section of this manual. CLOSE Photo Cell Use only UL325 compliant devices and follow all installation guidelines set forth by the manufacturer. Recommended Photo Sensor: DSW2000 Swing Gate Operator...
  • Page 20: Standard Reverse Connections

    1. Allows external input to reset gate operator during a Hard Shutdown. External 2. Allows external input to reset operator settings during Reset installation. Connecting External Reset Devices: 1. Connect Reset Button to RESET and COMMON. DSW2000 Swing Gate Operator...
  • Page 21: Access Control Connection

    Fire Input from closing the gate if in the open position. NOTE: Consult your local Fire Department for proper building codes and Fire Lock requirements. Connecting Access Devices: 1. Connect Fire Lock Control relays to FIRE and COMMON. (Most devices use Normally Closed & Common) DSW2000 Swing Gate Operator...
  • Page 22: Radio Receiver Connections

    1. Set Master DIP Switch 10 to ON. 2. Set Slave DIP Switch 10 to ON. 3. Connect Solenoids to SOLENOID NO and SOLENOID COM. 4. Connect Maglocks to MAGLOCK NC and MAGLOCK COM. Lock Power Switch 10: Solenoid Lock Power DSW2000 Swing Gate Operator...
  • Page 23: Alarm & Warning Light Connections

    2. Connect the Solar Panel positive to SOLAR + 3. Connect the Solar Panel negative to SOLAR - 12VDC, 20 Watt Batteries should be tested regularly for proper battery backup operation. Batteries should be replaced each year or as needed. DSW2000 Swing Gate Operator...
  • Page 24: Loops & Loop Detectors

     Seal the loop slots with a sealant. Make sure the sealant is able to sink to the bottom of the loop slot and completely 61’ to 240’ encase the loop wire. The wire should not move when the sealant has set. 241’ & Up DSW2000 Swing Gate Operator...
  • Page 25: Plug-In Loop Detector Connections

    3. Reverse Loop: Connect relay wires to REVERSE N.O. and COMMON. 4. Open Loop: Connect relay wires to OPEN N.O. and COMMON. 5. Set different frequencies for each loop detector. 6. Follow the directions provided by the external loop detector manufacturer for more detailed settings. DSW2000 Swing Gate Operator...
  • Page 26: Troubleshooting Tips

    4. Run a new CAT5 wire on top of the driveway to test the master slave communication. This will determine if the underground wire is good or bad. 5. Possible damage to the control board master slave components. Have boards repaired. DSW2000 Swing Gate Operator...
  • Page 27 You MUST read, understand and agree with ALL items in this limited warranty! FAAC warrants this product to be free of defects in workmanship and materials for a period of (5) five years from the date of purchase. FAAC reserves the right of final determination to the cause of any defect or failure. FAAC shall, at its option, either repair or replace this product if returned freight prepaid to FAAC during the warranty period.

Table of Contents