Approvals

8.4 XR-300M EEC mechanical stability (in operation)

8.4
XR-300M EEC mechanical stability (in operation)
The devices of the SCALANCE XR-300M EEC product group meet the following standards
(prerequisite: rack mounted with 4 securing points):
● IEC 60068-2-6
(vibrations during transportation and operation)
Test parameters:
5 – 9 Hz: 3.5 mm
9 – 150 Hz: 1 g
1 octave/min, 20 sweeps
● IEC 60068-2-27
(shocks during operation)
Test parameters:
15 g , 11 ms duration
6 shocks per axis
● IEC 60068-2-6
(vibrations during transportation)
Test parameters:
10 – 58 Hz: 0.075 mm
85 – 150 Hz: 1 g
1 octave/min, 20 sweeps