Technical data
6.2 Connectors and electrical data
Table 6- 8
Device version
(power supply)
1 x 24 to 48 VDC
2 x 24 to 48 VDC
1 x 100 to 240 VAC / 60 to 250 VDC
2 x 100 to 240 VAC / 60 to 250 VDC
Table 6- 9
Device version
(power supply)
24 to 48 VDC
100 to 240 VAC / 60 to 250
VDC
Table 6- 10
Device version
(power supply)
1 x 24 to 48 VDC
2 x 24 to 48 VDC
1 x 100 to 240 VAC / 60 to
250 VDC
2 x 100 to 240 VAC / 60 to
250 VDC
Table 6- 11
General
In the application range of EN 60255-27
50
Electrical data: Overcurrent protection
Electrical data: Signaling contact
Voltage via signaling contact
24 VDC
240 VAC
60 VDC
125 VDC
250 VDC
Plug-in terminal block for connectors of the power supply and signaling contact
Power supply
1 x 4-pin
2 x 4-pin
1 x 3-pin
2 x 3-pin
Overvoltage category
Overcurrent protection of the power supply
Non-replaceable fuse
1 x T2H / 250 V
2 x T2H / 250 V
1 x T2H / 250 V (AC)
1 x T2H / 300 V (DC)
2 x T2H / 250 V (AC)
2 x T2H / 300 V (DC)
Switching capacity
(resistive load)
max. 0.1 A
max. 5 A
max. 0.4 A
max. 0.22 A
max. 0.11 A
Signaling contact
1 x 2-pin
2 x 2-pin
1 x 3-pin
2 x 3-pin
Overvoltage category II
Overvoltage category III
Operating Instructions, 11/2015, A5E02661176-09