Notes on attaching a commercially available fixing jig

CAUTION
 Do not block the hole on the frame handle, as doing so could cause a failure due to heating.

6 Basic Operation

Start

WARNING
 Always make sure the tool is grounded.
No grounding the tool could cause failure or electric shock at the time of electrical leakage.
If you are not sure about the grounding of the outlet, request an electrical contractor to check if it is grounded.
When an extension cord is used, use a 3-core cord that includes a ground wire.
SP type
WARNING
 Before energizing, make sure that the signal cables are wired correctly in accordance with the instruction
manual.
If the power cable or other signal wires are energized while they are wired incorrectly, it could cause the tool to
fail.
1
Wire signal cables
Refer to "Example wiring of output signals" (p. 8).
2
Insert the power plug into an outlet (230 V AC)
Fixing position of fixing jig
Hole