QUBINO Flush 2 relay User Manual page 50

Z-wave
Table of Contents

Advertisement

Parameter no. 64 – Choose Normally Closed or Normally Open as Default for Q2 Load
Set value determines the type of the device connected to the Q2 output. The device type can
be normally open (NO) or normally closed (NC).
Values (size is 1 byte dec):
• default value 0
• 0 - When switch/device is off the output is 0V (NC).
• 1 - When switch/device is off the output is 230V (NO).
Parameter no. 110 – Temperature Sensor Offset Settings
Set value is added to or subtracted from the actually measured value to adjust the temperature
report sent by an external sensor (sold separately). This parameter only applies to the Celsius
temperature unit (the Fahrenheit unit is currently not supported).
Values (size is 2 byte dec):
• default value 32536
• 32536 - Offset is 0 °C.
• 1 - 100 – Where 1 stands for 0.1°C and 100 stands for 10.0 °C added to the actual
measurement.
• 1001 - 1100 – Where 1001 stands for -0.1 °C and 1100 stands for -10.0 °C subtracted
from the actual measurement.