Parameter no. 12 - Turn Load 1 (Q1) On Automatically with Timer
If Load (Q1) is OFF, you can schedule it to turn ON automatically after a period of time defined
in this parameter. The timer is reset to zero each time the device receives an OFF command,
either remotely (from the gateway (hub) or associated device) or locally from the switch.
Values (size is 2 byte dec):
• default value 0
• 0 - Auto ON Disabled
• 1 - 32535 = 1 - 32536 seconds (or milliseconds – see Parameter no. 15). Auto ON timer
enabled for a given amount of seconds (or milliseconds).
Parameter no. 13 - Turn Load 2 (Q2) Off Automatically with Timer
If Load (Q2) is ON, you can schedule it to turn OFF automatically after a period of time defined
in this parameter. The timer is reset to zero each time the device receives an ON command,
either remotely (from the gateway (hub) or associated device) or locally from the switch.
Values (size is 2 byte dec):
• default value 0
• 0 - Auto OFF Disabled
• 1 - 32535 = 1 - 32535 seconds (or milliseconds – see Parameter no. 15). Auto OFF timer
enabled for a given amount of seconds (or milliseconds).