Parameter no. 14 - Turn Load 2 (Q2) On Automatically with Timer
If Load (Q2) is OFF, you can schedule it to turn ON automatically after a period of time defined
in this parameter. The timer is reset to zero each time the device receives an OFF command,
either remotely (from the gateway (hub) or associated device) or locally from the switch.
Values (size is 2 byte dec):
• default value 0
• 0 - Auto ON disabled
• 1 - 32535 = 1 - 32536 seconds (or milliseconds – see Parameter no. 15). Auto ON timer
enabled for a given amount of seconds (or milliseconds).
Parameter no. 15 - Set Timer Units to Seconds or Milliseconds
Choose if you want to set the timer in seconds or milliseconds in parameters 11, 12, 13, and 14.
Values (size is 1 byte dec):
• default value 0
• 0 – timer set in seconds
• 1 – timer set in milliseconds
Please note that the value from this parameter applies to settings for Q1 and Q2 loads in all of
the above parameters (timer on / timer off).