Parameter no. 43 – Watt Power Consumption Reporting Time Threshold for Q2 Load
Set value refers to the time interval with which power consumption in Watts is reported (0 –
32535 seconds). If 300 is entered by default, energy consumption report will be sent to the
gateway (hub) every 300 seconds (5 minutes).
Values (size is 2 byte dec):
• default value 300
• 0 - Power consumption reporting disabled
• 1 - 32535 = 1 - 32535 seconds. Power consumption reporting enabled. Report is sent
according to time interval (value) set here.
Parameter no. 63 – Choose Normally Closed or Normally Open as Default for Q1 Load
Set value determines the type of the device connected to the Q1 output. The device type can
be normally open (NO) or normally closed (NC).
Values (size is 1 byte dec):
• default value 0
• 0 - When switch/device is off the output is 0V (NC).
• 1 - When switch/device is off the output is 230V (NO).