Electrical Diagram (110 - 230Vac, 24Vdc) - QUBINO Flush 2 relay User Manual

Z-wave
Table of Contents

Advertisement

9. Electrical Diagram (110 - 230VAC, 24VDC)

N
Neutral wire (+VDC)
L
Live (line) wire (-VDC)
Q1
Output for electrical device (load) no. 1
Q2
Output for electrical device (load) no. 2
I2
Input to control electrical device (in-wall switch) no.2
I1
Input to control electrical device (in-wall switch) no.1
TS
Temperature sensor terminal
*
Wago 221-413 splicing connectors for L and N connection must be used only when
connected to 230 VAC.
S
Service button
WARNING:
The service (S) button must NOT be used when the device is connected to a 110-230V power
supply.
The durability of the device depends on the applied load. For resistive loads (light bulbs, etc.)
and 4A current consumption of each individual electrical device, the product's lifespan exceeds
70,000 toggles for each individual load.
Notes for diagram: