Parameter no. 10 - Activate / deactivate ALL ON/ALL OFF Functionality
Flush 2 Relay device responds to commands ALL ON / ALL OFF that may be sent by the primary
or secondary gateway (hub) within the Z-Wave network.
Values (size is 2 byte dec):
• default value 255
• 255 - ALL ON active, ALL OFF active
• 0 - ALL ON not active, ALL OFF not active
• 1 - ALL ON not active, ALL OFF active
• 2 - ALL ON active, ALL OFF not active
Parameter no. 11 - Turn Load 1 (Q1) Off Automatically with Timer
If Load 1 (Q1) is ON, you can schedule it to turn OFF automatically after a period of time defined
in this parameter. The timer is reset to zero each time the device receives an ON command,
either remotely (from the gateway (hub) or associated device) or locally from the switch.
Values (size is 2 byte dec):
• default value 0
• 0 - Auto OFF Disabled
• 1 - 32535 = 1 - 32535 seconds (or milliseconds – see Parameter no. 15). Auto OFF timer
enabled for a given amount of seconds (or milliseconds).
44
EN.