2.3.4

iRMC S5-specific commands

F5 10 - Get System Status
This command returns a variety of internal information on the system such as the
power state, error status, etc.
Request Data
Response Data
The Timestamp is only relevant for evaluating the Notifications Byte.
System Status
Bit 7 - System ON
Bit 6 -
Bit 5 -
Bit 4 - SEL entries available
Bit 3 -
Bit 2 - Watchdog active
Bit 1 -
Bit 0 - Post State
F5 12 - Get EEPROM Version Info
This command returns information on the current versions (bootloader, firmware and
SDR) stored in the EEPROM(s).
Cisco C880 M5 Configuration Guide
-
B8
NetFnlLUN: OEM/Group
F5
Cmd : Command Group Memory
-
1:3 80 28 00
IANA-Enterprise-Number FTS, LS byte first
4
10
Command Specifier
5:8 Timestamp
-
BC
F5
-
1
Completion Code
2:4 80 28 00
IANA-Enterprise-Number FTS, LS byte first
5
System Status
6
Signaling
7
Notifications
8
POST Code
Signaling
Localize LED
CSS LED
CSS LED
Global Error LED New Output on LocalView display
2.3 Supported IPMI OEM Commands
Notifications
SEL Modified (new SEL entry)
SEL Modified (SEL Cleared)
SDR Modified
Nonvolatile IPMI variable modified
ConfigSpace modified
22