Power off
Source
0x04
0x05
0x08
0x0C
0x1D
0x24
0x25
01 1C - Set Power Off Inhibit
This command sets the Power Off Inhibit flag, which temporarily suppresses any
unfounded attempt to power down the server.
If the Power Off Inhibit flag is set, the firmware saves the cause of any attempt to
perform a Power Off, Power Cycle or restart of the server, but does not perform the
action. The cause of the most recent attempt to perform a Power Off, Power Cycle or
restart of the server is always saved at any given time. The stored action is only
performed when the Power Off Inhibit flag is reset.
The Power Off Inhibit flag is automatically reset after a power failure or when the reset
button is pressed.
The effect of the Power Off Inhibit flag is the same as that of the Dump flag used
when creating a main memory dump. In this case, the initiator must set the flag
before making the dump and reset it when the dump is complete.
Request Data
Response Data
Cisco C880 M5 Configuration Guide
Description
Fan failure
Critical temperature
Final power-off after repeated watchdog timeouts
Final power-off after repeated CPU errors
Powered off by remote control via remote manager
Automatic Power on/off for VIOM Inventory Boot
Automatic Power on/off for VIOM Init Boot
-
B8
NetFn|LUN: OEM/Group
-
01
Cmd : Command Group Communication
1:3 80 28 00
IANA-Enterprise-Number FTS, LS Byte first
4
1C
Command specifier
5
00
Object ID
6:7 00 00 Value ID
8
01
Data length
9
Power Off Inhibit Flag: 0 no Inhibit, 1 Inhibit
BC
-
01
-
1
Completion code
2:4 80 28 00
IANA-Enterprise-Number FTS, LS Byte first
2.3 Supported IPMI OEM Commands
17