Preparation for Use

Equipment configurations for non-CBRN use are detailed in a NIOSH Approval Table
(refer to instruction no. 3356261). Configurations for CBRN use are detailed later
in this instruction (refer to CBRN Use).
Installing the Back-Up Battery
Orientate the SCBA to access the battery compartment.
Unscrew and remove the battery cap (1, Fig 2), using a suitable coin.
Insert the battery, +ve terminal end first, into the battery compartment.
Refit and secure the battery cap. Do not overtighten.
1
Installing the Main Battery
Orientate the SCBA to access the pressure module (1, Fig 3).
Inspect the terminals on the battery and pressure module, and the sealing rim around
the battery terminals (all must be clean and undamaged).
Locate the two slots in the top of the battery pack (2) on the tabs in the battery
housing.
Firmly press the battery into position until an audible click is heard, to indicate a
secure attachment. The Sentinel 7000 will emit a single tone and will commence
the self-check sequence (refer to Sentinel 7000 Self Check).
Press and hold the RH and LH buttons of the user interface until the display clears,
then immediately release the buttons.