PSS® 7000 SERIES c/w SENTINEL 7000 EMU
3

Technical Data

High Pressure (HP) Connections
The following SCBA HP connections are available for associated compressed air cylinder
assemblies.
2216 psig connection to CGA 346
4500 psig connection to CGA 347
Quick Connect – 2216psig or 4500psig (Option) – Refer to User Instruction.
Power Supplies
Main battery – 7.5 V
Back-up battery – 3 V
Head-up display battery – 3 V.
RIC UAC Connection
2216 psi or 4500 psi male, quick-release coupling with pressure relief valve
(PRV).
LDR to Face mask Connection
Dräger push-in connector.
Pressure and Flow Details
Medium pressure – 87 psi to 130 psi
Air flow – In excess of 1000 litres/minute
Air flow at 290 psi – In excess of 500 litres/minute.
EOST Alarms
Activation commencement range (mechanical and electronic):
2216 psi cylinder – 600 psi to 510 psi
4500 psi cylinder – 1215 psi to 1035 psi.
General Information
Batteries
Danger of explosion. Do not change the batteries in an explosive or flammable
!
atmosphere.
Do not dispose of batteries in a fire. Batteries must be disposed of in line with
!
local regulations.
Do not attempt to recharge any non-rechargeable battery.
!
Battery information:
Main battery
Back-up battery
HUD battery
Sentinel 01: Edition 1: July 2008 - Subject to Modification
7.5 V (5 x 1.5 V AA alkaline batteries)
3 V (CR123 lithium battery)
3 V (CR123 lithium battery).