PSS® 7000 SERIES c/w SENTINEL 7000 EMU
Disconnect the hose of the independent air supply from the male coupling of the airline
hose connection. Breathe normally and immediately leave the hazardous area by the
shortest and safest route.
Safety Warning: The remaining duration begins from the time of opening the cylinder
valve and disconnecting the independent air supply. The time required to allow the
wearer to escape to a safe area must be within the remaining air capacity (volume)
of the cylinder taking into account the breathing rate of the wearer.
15
RIC UAC Use
Use of the RIC UAC should be by trained and competent personnel only.
The RIC UAC filling hose is a required component of the NFPA 1981 certification.
Only use a filling hose which has been certified to NFPA 1981 for use in immediately
dangerous to life or health (IDLH) atmospheres.
Do not use the RIC UAC connection for second person (buddy-breather).
Do not use the RIC UAC support pack to transfer air from one compressed air breathing
apparatus to another.
Do not allow oil, grease or other contaminants to contact the RIC UAC connection.
Do not attempt to disassemble or repair the RIC UAC connection.
Caution: The secondary air supply pressure to the RIC UAC must not exceed maximum
rated working pressure of the cylinder(s) being filled.
Caution: If the pressure relief valve of the RIC UAC is activated, the SCBA must be
returned to the nearest Dräger branch or agent.
Caution: If a leak is detected while refilling in a contaminated or oxygen-deficient
gaseous atmosphere, stop refilling and immediately leave the hazardous area.
16

Contact Details

Any issues with the equipment, including damage, malfunction, or failure of the
breathing apparatus that may present a hazard to the user should be reported to:
Draeger Safety, Inc.
101 Technology Drive
Pittsburgh
PA15275
Phone: 1-800-922-5518
Fax: 1-800-922-5519
Contact with the certification organisations may be reached at:
NIOSH, NPPTL
Phone: 1-800-232-4636
SEI (NFPA)
1307 Dolley Madison Blvd
Suite 3A, McLean
VA 22101
Phone: 1-703-442-5732
Sentinel 01: Edition 1: July 2008 - Subject to Modification