Advantech ASR-5300I Series User Manual page 90

3u 16-bay ip-san storage with reinforced reliability
Table of Contents

Advertisement

6.
Insert the new controller module. Carefully push the controller until you feel the
contact resistance when the board edge connectors are engaging the back-
plane. Push the ejection levers upward (indicated by the blue arrows) and fas-
ten the retention screw on the ejection levers.
7.
Reattach all cables.
8.
For single-controller models or when replacing both controllers simultaneously,
power on the system. Check for system messages on the LCD screen, SAN-
Watch, or firmware menu-driven utility. When the replacement controller is suc-
cessfully brought online, the power-on status LEDs should turn on.
9.
For single-controller models or when replacing both controllers simultaneously,
restor NVRAM data. To restore previous ID/LUN mapping settings, users may
use the "Restore NVRAM from Disks" or "Restore NVRAM from Files" functions
in the firmware. ID/LUN mapping will be restored.
ASR-5300I Series Hardware User Manual