A.3
Fault Tolerance for RAID Models
Drive S.M.A.R.T Support
CBM (Cache Backup Module)
ISEMS (IStorage Simple
Enclosure Management Service)
via I2C interface
Automatic Drive Failure Detection
Automatic Rebuild on Spare Drives
Regenerate Logical Drive Parity
Bad Block Reassignment
Manual and Automatic Rebuild upon
Failed Drive Replacement
Manual Clone of
Suspected Failed Drive
Concurrent Rebuild on Multiple
Drives in a RAID (0 + 1) Logical Drive
Salvage the Second Temporary
Failed Drive in a RAID 1, 3, 5 or 6
Logical Drive
Salvage the First Temporary Failed
Drive in a RAID 0 Logical Drive
A.4
Power Supply
2U/3U Systems
Input Voltage
Frequency
Power Rating
DC Output
Input Frequency
AC Input
Power Factor Correction
Hold-Up Time
Over-Temperature Protection
*The PSU specifications described above are general measurements and may not
represent all models. For details, please refer to specific model specifications.
ASR-5300I Series Hardware User Manual
Yes, with user-configurable detect-only, clone and
replace, and perpetual clone functions.
Yes (R models only, optional accessory for single
controller models)
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Dual-controller model:
100VAC @ 10A
240VAC @ 5A with PFC (auto-switching)
Single-controller model:
100VAC @ 10A
240VAC @ 5A with PFC (auto-switching)
50 to 60Hz
460W
12.0V: 38A (Max.)
5.0 VSB: 2A (Max.)
50 to 60Hz
100VAC @ 10A or 240VAC @ 5A with PFC
Yes
At least 12ms at 115/230VAC full load after a loss of
AC input
Auto shutdown when lost cooling or exceeded ambient
temperature; over-voltage protection is also available.