Installation
2.3 Installation on the DIN rail
Installation
1. Insert the SIM card, see section "SIM card (Page 27)".
2. Place the third housing guide of the device on the top edge of the DIN rail
3. Press the device down against the DIN rail until the spring catch locks in place
4. Connect the power supply, refer to the section "Power supply (Page 28)".
5. Fit the connectors for the digital input and digital output, refer to the section "Digital
input/output (Page 30)".
6. Connect the antenna, refer to the section "Antennas (Page 32)".
7. Connect the device to the local network, refer to the section "Ethernet port (Page 35)".
8. Connect the terminal with as short a cable as possible ≤ 150 mm and a large cross-
sectional area ≥ 2.5 mm² to the ground of the system, see section "Grounding (Page 29)"
Dismantling
1. Disconnect all connected cables.
2. Using a screwdriver, pull down the catch on the rear of the device.
3. Pull lower part of the device away from the DIN rail.
20
RUGGEDCOM RM1224
Operating Instructions, 10/2016, RC1260-EN-02
.
.