AccessZone® - PcManagement™ User Manual
Rights and settings are filled out for the user:
Select whatever the user must use PIN code to get access or just within a specified PIN code time.
The PIN code time can be the same or set differently for each GateController™. I.e. PIN code may
be required at different times depending on the GateController's location in the system.
Select which options the user must use (no options are selected by default):
"Use Access Keep Open Time" will allow the user to keep the door/gate open within the
specified time period
"Use Access Calendar" will enforce the user to comply with the GateController calendar
"Use Silent PIN Access" will allow the user to enter a special "silent" access PIN code. The
user must type the PIN code 4 times to activate. The door/gate will be open as normal but
an alarm is trigged in the system to alert system administer/security personal
"Use Alarm System ON/OFF" will allow the user to switch an alarm system ON and OFF
Last select the device power class for the user (device):
Class 1 = "strong device" Class 2 = "standard device" Class 3 = "weak device"
If a user's device must be closer to the reader than most others before access is granted
- select class 3 = "weak device".
If a user's device gives access further away from the reader than most others
- select class 1 = "strong device".
Click "Add" to add the user or "Cancel" to leave without adding the user.
TIP!
A mobile phone is typically a class 2 device. If you are in doubt select Class 2 (default).
Remember a feature must also be enabled in the GateController™ for it to work.
All information is subject to change without notice. All other products and brand names are registered trademarks of their respective companies
Copyright © 2005-2014 All rights reserved MVC-Data ApS Skalhuse 5 9240 Nibe Denmark Web www.mvc-data.com E-mail info@mvc-data.com Phone +45 25 12 84 02
2014-03-13 US 0.17